1.1 : Buildings Sector Energy Consumption
| 1.1.4 |
2010 U.S.
Buildings Energy End-Use Splits, by Fuel Type (Quadrillion Btu) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Natural |
Fuel |
|
Other |
Renw. |
Site |
|
Site |
|
Primary |
Primary |
|
|
|
|
Gas |
Oil (1) |
LPG |
Fuel(2) |
En.(3) |
Electric |
|
Total |
Percent |
Electric (4) |
|
Total |
Percent |
| Space Heating
(5) |
5.14 |
0.76 |
0.30 |
0.10 |
0.54 |
0.72 |
|
7.56 |
37.0% |
| |
2.24 |
|
9.07 |
22.5% |
|
| Space Cooling |
|
0.04 |
|
|
|
|
1.92 |
|
1.96 |
9.6% |
| |
5.94 |
|
5.98 |
14.8% |
|
| Lighting |
|
|
|
|
|
|
|
1.88 |
|
1.88 |
9.2% |
| |
5.82 |
|
5.82 |
14.4% |
|
| Water Heating |
|
1.73 |
0.13 |
0.07 |
|
0.04 |
0.54 |
|
2.51 |
12.3% |
| |
1.67 |
|
3.63 |
9.0% |
|
| Refrigeration
(6) |
|
|
|
|
|
|
0.84 |
|
0.84 |
4.1% |
| |
2.62 |
|
2.62 |
6.5% |
|
| Electronics (7) |
|
|
|
|
|
|
0.81 |
|
0.81 |
3.9% |
| |
2.49 |
|
2.49 |
6.2% |
|
| Ventilation (8) |
|
|
|
|
|
|
0.54 |
|
0.54 |
2.6% |
| |
1.66 |
|
1.66 |
4.1% |
|
| Computers |
|
|
|
|
|
|
0.38 |
|
0.38 |
1.9% |
| |
1.19 |
|
1.19 |
2.9% |
|
| Cooking |
|
|
0.39 |
|
0.03 |
|
|
0.21 |
|
0.63 |
3.1% |
| |
0.64 |
|
1.06 |
2.6% |
|
| Wet Cleaning
(9) |
0.06 |
|
|
|
|
0.33 |
|
0.38 |
1.9% |
| |
1.01 |
|
1.06 |
2.6% |
|
| Other (10) |
|
0.30 |
0.01 |
0.30 |
0.05 |
0.02 |
0.89 |
|
1.58 |
7.7% |
| |
2.76 |
|
3.45 |
8.6% |
|
| Adjust to SEDS
(11) |
0.68 |
0.25 |
|
|
|
0.44 |
|
1.37 |
6.7% |
| |
1.35 |
|
2.28 |
5.7% |
|
| Total |
|
|
8.35 |
1.14 |
0.70 |
0.15 |
0.59 |
9.49 |
|
20.43 |
100% |
| |
29.39 |
|
40.33 |
100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Note(s): |
1)
Includes distillate fuel oil (1.06 quad) and residual fuel oil (0.08 quad).
2) Kerosene (0.04 quad) and coal (0.07 quad) are assumed attributable to
space heating. Motor gasoline (0.05 quad) assumed attributable to other
end-uses. 3) Comprised of wood space heating (0.42 quad), biomass (0.11),
solar water heating (0.04 quad), geothermal space heating (less than 0.01
quad), solar photovoltaics (PV) less than 0.02 quad), and wind (less than
0.01 quad). 4) Site-to-source electricity conversion (due to generation and
transmission losses) = 3.10. 5) Includes furnace fans (0.42 quad). 6)
Includes refrigerators (2.36 quad) and freezers (0.26 quad). Includes
commercial refrigeration. 7) Includes color television (1.02 quad) and other
office equipment (0.81 quad). 8) Commercial only; residential fan and pump
energy use included proportionately in space heating and cooling. 9) Includes
clothes washers (0.10 quad), natural gas clothes dryers (0.06 quad), electric
clothes dryers (0.60 quad) and dishwashers (0.31 quad). Does not include
water heating energy. 10) Includes residential small electric devices,
heating elements, motors, swimming pool heaters, hot tub heaters, outdoor
grills, and natural gas outdoor lighting. Includes commercial service station
equipment, ATMs, telecommunications equipment, medical equipment, pumps,
emergency electric generators, combined heat and power in commercial
buildings, and manufacturing performed in commercial buildings. 11) Energy
adjustment EIA uses to relieve discrepancies between data sources. Energy
attributable to the residential and commercial buildings sector, but not
directly to specific end-uses. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DOWNLOAD TABLE AS PDF XLS
Related Tables:
Sources:
| EIA, National Energy Modeling System (NEMS) for AEO 2012 Early Release, Jan. 2012
|
| BTS/A.D. Little, Electricity Consumption by Small End-Uses in Residential Buildings, Aug. 1998, Appendix A for residential electric end-uses
|
|
|
|
|